Cases reported "Foreign-Body Migration"

Filter by keywords:



Filtering documents. Please wait...

1/251. Central venous catheter-associated thrombosis in severe haemophilia.

    Significant subclavian vein thromboses associated with indwelling fully implanted (port-a-cath) devices are described in two boys with severe haemophilia A and factor viii inhibitors. Investigations were prompted by prominent chest wall veins in one case, whereas the thrombosis was a chance finding in the other case during investigation of mechanical dislocation of the catheter tubing. Extensive collateral venous circulations were demonstrated by venography in both instances indicating that the thrombus had been present for some time. Possible contributing factors to the thromboses included desensitization therapy (both patients), high-dose FEIBA (in one patient) and use of lower doses of heparin for line flush than that recommended by some authors. Neither patient had a familial or non-familial predisposition to thrombosis.
- - - - - - - - - -
ranking = 1
keywords = chest
(Clic here for more details about this article)

2/251. An unusual presentation of a foreign body in the urinary bladder: A migrant intrauterine device.

    A 35-year-old woman, who had had an intrauterine device inserted 7 years earlier, presented with dysuria, pollakiuria, suprapubic pain and urethral irritation. The intrauterine device was found in the bladder with stone formation and was removed by endoscopy.
- - - - - - - - - -
ranking = 0.27023494583018
keywords = pain
(Clic here for more details about this article)

3/251. Proximal migration of transanastomotic pancreatic stent following pancreaticoduodenectomy and pancreaticojejunostomy.

    BACKGROUND: The use of catheters to stent the pancreaticojejunal anastomosis following pancreaticoduodenectomy is practiced by some surgeons. Their long-term effects in this setting, however, remain unknown. methods: A 60-yr-old woman underwent a potentially curative pylorus preserving pancreaticoduodenectomy for Stage I ampullary carcinoma. Roux-en-Y pancreaticojejunostomy was constructed over a short stent. She presented 4 yr later with abdominal pain, steatorrhea, and weight loss. Computed tomography revealed a stent within the proximal pancreatic duct, with gross upstream ductal dilatation and parenchymal features of chronic pancreatitis. RESULTS: laparotomy revealed no disease recurrence. The stent, removed through a jejunotomy, was occluded. On-table pancreatogram demonstrated a 3-cm proximal duct stricture. drainage was achieved with a lateral pancreaticojejunostomy (modified Puestow procedure). Recovery was uneventful, with clinical recovery of pancreatic exocrine function at 6 mo follow-up. CONCLUSION: Proximal migration of transanastomotic pancreatic stent with subsequent development of chronic pancreatitis is a potential complication following pancreaticoduodenectomy. It can be managed effectively with stent removal and a lateral pancreaticojejunostomy.
- - - - - - - - - -
ranking = 0.27023494583018
keywords = pain
(Clic here for more details about this article)

4/251. A complication of pectus excavatum operation: endomyocardial steel strut.

    An 18-year-old patient who had correction of pectus excavatum deformity in our department 4 years earlier was admitted because of stabbing chest pain. He had not attended to postoperative controls and had not come for extraction of the steel strut, although he had been contacted. He was diagnosed to have a broken steel strut, and the strut was noted to be embedded in the myocardium. This unreported complication of pectus excavatum operation forced us to review sternal support techniques.
- - - - - - - - - -
ranking = 2.1303755251156
keywords = chest, chest pain, pain
(Clic here for more details about this article)

5/251. Delayed pneumothorax and hydrothorax with central venous catheter migration.

    We report a case of delayed pneumothorax, central venous catheter migration and iatrogenic hydrothorax in a 22-year-old female. The left subclavian central venous catheter initially transfixed the lung apex; pneumothorax occurred 24 h later following initiation of positive pressure ventilation. lung collapse as a result of the pneumothorax caused catheter migration and hydrothorax. Catheter removal and chest drainage led to an uneventful recovery.
- - - - - - - - - -
ranking = 1
keywords = chest
(Clic here for more details about this article)

6/251. Intrapulmonary artery and intrabronchial migration and extraction of a fragment of J-shaped atrial pacing catheter.

    A fragment of a fractured Telectronics Atrial Accufix 330-801 lead asymptomatically perforated the adjacent bronchus and was detected on routine chest X-ray. The metallic fragment was located by chest CT scan and bronchial fluoroscopy to lie between the right lobar bronchus and the pulmonary artery, confirming bronchial perforation. The foreign body was removed without complication by direct visualisation with rigid bronchoscopy.
- - - - - - - - - -
ranking = 2
keywords = chest
(Clic here for more details about this article)

7/251. Intrapericardial tumbling bullet.

    foreign bodies of the pericardium are rare and they are associated most commonly with significant trauma. The diagnosis of a pericardial foreign body can be difficult. One must distinguish between foreign matter in the cardiac chamber or free-floating in the mediastinum. Serial chest x-rays and fluoroscopy were most helpful to us. Neither CT scan nor an echocardiogram were particularly helpful. To prevent pericarditis, either sterile or non-sterile, with potential for other significant complications, removal of a pericardial foreign body is always indicated.
- - - - - - - - - -
ranking = 1
keywords = chest
(Clic here for more details about this article)

8/251. Late traumatic intraocular lens extrusion after penetrating keratoplasty.

    BACKGROUND: Penetrating keratoplasty places a patient at risk for wound rupture from blunt trauma because the graft-host interface remains weakened for years after the surgery. Violent environments, contact sports, and strenuous activity put patients with compromised corneal structural integrity at high risk of traumatic injury. CASE REPORT: This case report presents a 42-year-old penetrating keratoplasty patient with a history of homelessness, polysubstance abuse, and domestic violence. This patient experienced a ruptured globe at the graft-host junction secondary to a direct blow by a fist, which extruded the intraocular lens from the eye. After emergency wound closure, the graft continued to degrade until bullous keratopathy developed. With little visual recovery potential for this graft, a Gunderson conjunctival flap procedure was implemented to decrease chronic ocular pain. CONCLUSIONS: After penetrating keratoplasty, patients should be periodically reminded of the susceptibility of the graft wound to injury from high-risk activity and violence. Constant use of protective eyewear should be recommended to corneal transplant recipients.
- - - - - - - - - -
ranking = 0.27023494583018
keywords = pain
(Clic here for more details about this article)

9/251. Wandering intraspinal bullet.

    A case of gun shot injury to the spine, with the bullet entering the thecal sac via the right side of the lower chest and wandering freely in the subarachnoid space, is reported. The patient was neurologically intact initially and developed radicular symptoms with foot drop and urinary retention on the third day after injury. The radiological findings and the problems faced at surgery are discussed, and the relevant literature of this uncommon condition is reviewed.
- - - - - - - - - -
ranking = 1
keywords = chest
(Clic here for more details about this article)

10/251. Late stent malapposition occurring after intracoronary beta-irradiation detected by intravascular ultrasound.

    We report a case of late stent malapposition occurring 6 months after intracoronary beta-irradiation detected by three-dimensional intravascular ultrasound, in spite of good apposition immediately after the procedure. Volumetric quantification revealed that stent volume remained unchanged, whereas total vessel volume increased by 13% after 6 months within the stent area. The increase of the vessel volume took place mainly in the proximal part of the stent, where the malapposition was located.
- - - - - - - - - -
ranking = 0.017247650298887
keywords = area
(Clic here for more details about this article)
| Next ->


Leave a message about 'Foreign-Body Migration'


We do not evaluate or guarantee the accuracy of any content in this site. Click here for the full disclaimer.