Cases reported "Dermatitis, Occupational"

Filter by keywords:



Filtering documents. Please wait...

1/14. Identification of sensitizing diethyleneglycol maleate in a two-component polyester cement.

    Unsaturated polyester (UP) cement caused allergic contact dermatitis in car repair work. The resin was a condensate of polyols and maleic anhydride with reactive solvent, auxiliary substances, and inorganic reinforcement substances. To identify the causative chemicals, the cement was tested on a sensitized patient. For analysis, samples of the resin were eluted with acetone and eluted with hexane to precipitate inorganic material and large polyester molecules. The eluate was evaporated. The remainder, dissolved in acetone, was separated into fractions on silica plates by thin layer chromatography (TLC). On the developed (hexane/chloroform, 15/85) plates, 20 bands were obtained under UV-light at 254 nm. Samples of the bands were scraped and used for patch testing. The scraping at a retention factor (Rf) of 0.24 caused a skin reaction. The bands at this retention were removed from six plates, combined, eluted with acetone and purified again by TLC. The purified fraction mixed in petrolatum in the dilution series was used for conclusive patch testing on the patient. An allergic reaction was induced at down to 0.003% wt/wt. According to MS and IR analyses, the isolated compound was diethyleneglycol maleate (DEGM, MW204). In addition to the resin part, the sanding dust also contained this monomer.
- - - - - - - - - -
ranking = 1
keywords = chromatography
(Clic here for more details about this article)

2/14. Gas chromatography: an investigative tool in multiple allergies to essential oils.

    Essential or fragrant oils are volatile odourous mixtures of organic chemical compounds that are widely used in aromatherapy and in the perfume industry. Because of their frequent use, allergy to essential oils is being increasingly recognized. We report 2 cases of multiple allergies to essential oils in professional aromatherapists. Gas chromatography/mass spectrometry was used to analyse the oils in order to identify a common allergen responsible for the contact dermatitis. In both the cases, alpha- and beta-pinene were found to be the most common constituent in the oils and thus appeared to be key allergens. alpha-pinene was confirmed as an allergen on repeat patch testing with pure alpha-pinene in both cases. 12 controls tested were negative for the same. gas chromatography-mass spectrometry was found to be an extremely useful tool that could be utilized in investigating multiple allergies to essential oils.
- - - - - - - - - -
ranking = 6
keywords = chromatography
(Clic here for more details about this article)

3/14. erythema multiforme due to contact with weeds: a recurrence after patch testing.

    erythema multiforme (EM) as a complication of patch testing (PT) is rare. A 52-year-old woman with a 13-year history of episodes of EM, after contact with weeds during home gardening, had had no recent history of herpes simplex, other infection, drug ingestion or vaccination. On examination, EM lesions were distributed on the exposed skin. 5 weeks after complete resolution, PT and photopatch testing (PPT) were done with fresh plants she brought in. She was PT with a standard series and the Hermal-Trolab plants, woods, tars, balsams and flavors series. Intradermal testing, with a 3 reaction to mixed weed pollens, was done 3 weeks later. Specific IgE to weed pollens class 1 (CAP-Pharmacia) was detected. Eczematous PT reactions were obtained with fresh leaves: common chickweed (stellaria media caryophyllaceae), dandelion (taraxacum officinale Compositae), field-milk thistle (sonchus arvensis Compositae) and white clover (trifolium repens Leguminosae). Photoaggravation was seen to common chickweed and dandelion. Positive PT was also seen with alantolactone. By the 4-day reading, a typical EM had commenced, coming up to quite the same extent as seen on admission. There was no photosensitivity (UV skin tester, K. Waldmann). In the essential oil obtained from common chickweed, thin layer chromatography (TLC) revealed the well-known contact allergens borneol, menthol, linalool, 1,8-cineole, and other terpenes such as epoxy-dehydro-caryophyllene, monoterpene alcohol-ester and caryophyllene. Up to now, no data on essential oil in stellaria media (common chickweed) have been reported. It can be concluded that EM developed due to contact with weeds, and recurred after patch testing. Neither blistering nor eczematous lesions have been seen on her skin, making this case very unusual. As far as the world literature is concerned, this is only the 4th report of EM developing in association with patch testing.
- - - - - - - - - -
ranking = 1
keywords = chromatography
(Clic here for more details about this article)

4/14. Alantolactone sensitivity in chrysanthemum contact dermatitis.

    A case of occupational chrysanthemum contact dermatitis is reported. patch tests showed the patient to be sensitized to chrysanthemum morifolium (Chr M) leaves, flowers, and stems (alcoholic extracts) and to alantolactone. An attempt at desensitization appears to have been successful. Gas chromatography indicated the presence of alantolactone in all the various parts of Chr M, mostly in the flowers. The "maximization test" succeeded in sensitizing guinea pigs to alantolactone.
- - - - - - - - - -
ranking = 1
keywords = chromatography
(Clic here for more details about this article)

5/14. Occupational allergic contact dermatitis from bisphenol A in vinyl gloves.

    Allergic contact dermatitis caused by polyvinyl chloride gloves is rarely reported, and in only 2 cases was bisphenol A considered to be the responsible sensitizer. We report a patient with occupational hand dermatitis after the use of a new type of high-density vinyl (HDV) gloves. patch tests showed positive ( ) reactions to both used and new HDV gloves and to bisphenol A. Chemical analysis by gas chromatography-mass spectrometry demonstrated the presence of bisphenol A in the HDV gloves. Replacement by nitrile rubber gloves resulted in complete clearance of the hand dermatitis.
- - - - - - - - - -
ranking = 1
keywords = chromatography
(Clic here for more details about this article)

6/14. Occupational contact dermatitis from a grease.

    BACKGROUND: Contact allergy to grease is rare and often not even suspected. We investigated such a case in which the detected allergen was the stabilizer in the grease, which is rarely found as an allergen. OBJECTIVE: Thin-layer chromatography (TLC) was used in a novel way and helped detect the allergen. methods: Patch testing with our standard series, a metal-working series, the different substances individually, the grease in serial dilution and extracts of personal objects, the TLC plate. gas chromatography-mass spectrometry was also used. RESULTS: Test results indicated contact allergy to grease containing N-phenyl-1-naphthylamine and contact allergy to Disperse Orange 1, N-cyclohexyl-N'-phenyl-4-phenylenediamine, N-isopropyl-N'-phenyl-4-phenylenediamine, and N,N'-diphenyl-4-phenylenediamine. CONCLUSION: N-phenyl-1-naphthylamine was the main cause of the patient's dermatitis. This case report underlines the importance of testing the patient's own products and also underlines the benefit of using TLC strips for patch testing and of visiting the workplace to get correct information about exposure conditions.
- - - - - - - - - -
ranking = 2
keywords = chromatography
(Clic here for more details about this article)

7/14. Occupational allergic contact dermatitis from antioxidant amines in a dental technician.

    We describe an 18-year-old dental technician who presented with dry hyperkeratotic lesions on his left palm that were limited to an area that was in contact with a container in which he had prepared the molds for a dental prosthesis. On patch testing, he had a positive reaction to black rubber mix and its components N-cyclohexyl-N'-phenyl-4-phenylenediamine, N,N'-diphenyl-4-phenylenediamine, and N-isopropyl-N'-phenyl-4-phenylenediamine, as well as to a piece of the rubber container. Thin-layer chromatography (TLC) of a piece of the rubber container confirmed the presence of the para-phenylenediamine mix. Results of patch-testing with TLC were positive after 48 and 96 hours. The lesions resolved when the patient stopped using the container. The patient was diagnosed with occupational allergic contact dermatitis. We also review the dermatoses caused by antioxidant amines.
- - - - - - - - - -
ranking = 1
keywords = chromatography
(Clic here for more details about this article)

8/14. Occupational dermatitis due to an epoxy acrylate.

    A dental assistant developed sensitivity to dental restorative materials within 3 months of starting to use them. They contained the epoxy acrylate BIS-GMA, which is the most commonly used dimethacrylate monomer in dental composite restorations. She was positive to a patch test with BIS-GMA, which was the probable allergen, and epoxy resin, but this substance was not present in the materials used, as shown by high performance liquid chromatography. The patient was also allergic to the disinfectant Desimex i containing dodecyl diaminoethyl glycine.
- - - - - - - - - -
ranking = 1
keywords = chromatography
(Clic here for more details about this article)

9/14. Occupational allergic contact dermatitis from alkanolamineborates in metalworking fluids.

    Alkanolamineborates are extensively used in coolants as corrosion inhibitors. In this paper, 3 machinists with contact allergy to alkanolamineborates are reported. To avoid false-positive test reactions due to the alkalinity of the alkanolamineborates, they should be tested when dissolved in an acidic buffer. When various alkanolamineborates were tested in dilution series in the 3 patients, 2 types of reactivity patterns emerged, indicating the existence of at least 2 separate sensitizers in alkanolamineborates. The raw materials, ethanolamines and boric acid, did not yield any positive patch test reactions. Thin-layer chromatography investigations demonstrated that each alkanolamineborate consists of many substances, which differed in part between different alkanolamineborates. The present study shows that it is not possible to use 1 particular alkanolamineborate for tracing contact allergy to alkanolamineborates in general.
- - - - - - - - - -
ranking = 1
keywords = chromatography
(Clic here for more details about this article)

10/14. Identification of causative chemicals of allergic contact dermatitis using a combination of patch testing in patients and chemical analysis. Application to cases from rubber gloves.

    5 cases of allergic contact dermatitis from rubber gloves were investigated by our recommended procedures using a combination of patch testing in patients and chemical analysis of causative rubber products by gas chromatography (GC) and high-performance liquid chromatography (HPLC). We previously confirmed that zinc ethylphenyldithiocarbamate (ZEPC), a dithiocarbamae-type accelerator (DTC), was causative in a case of allergic contact dermatitis from rubber work gloves. Subsequently, we have clarified that DTCs such as zinc dimethyldithiocarbamate (ZDMC), zinc diethyldithiocarbamate (ZDEC) and zinc dibutyldithiocarbamate (ZDBC) and amines such as dimethylamine (DMA), diethylamine (DEA) and piperidine (PIP) were also causative in cases from surgical rubber gloves. Thus, our investigative studies revealed that, although thiurams have been taken much more notice of as allergenic compounds than their corresponding DTCs and amines, not only DTCs such as ZDMC, ZDEC, ZDBC and ZEPC, but also amines such as DMA, DEA and PIP were noteworthy causative candidates of allergic contact dermatitis from rubber gloves.
- - - - - - - - - -
ranking = 2
keywords = chromatography
(Clic here for more details about this article)
| Next ->


Leave a message about 'Dermatitis, Occupational'


We do not evaluate or guarantee the accuracy of any content in this site. Click here for the full disclaimer.