Cases reported "Illusions"

Filter by keywords:



Filtering documents. Please wait...

1/3. vertigo in virtual reality with haptics: case report.

    A researcher was working with a desktop virtual environment system. The system was displaying vector fields of a cyclonic weather system, and the system incorporated a haptic display of the forces in the cyclonic field. As the subject viewed the rotating cyclone field, they would move a handle "through" the representation of the moving winds and "feel" the forces buffeting the handle as it moved. Stopping after using the system for about 10 min, the user experienced an immediate sensation of postural instability for several minutes. Several hours later, there was the onset of vertigo with head turns. This vertigo lasted several hours and was accompanied with nausea and motion illusions that exacerbated by head movements. Symptoms persisted mildly the next day and were still present the third and fourth day, but by then were only provoked by head movements. There were no accompanying symptoms or history to suggest an inner ear disorder. physical examination of inner ear and associated neurologic function was normal. No other users of this system have reported similar symptoms. This case suggests that some individuals may be susceptible to the interaction of displays with motion and movement forces and as a result experience motion illusions. Operators of such systems should be aware of this potential and minimize exposure if vertigo occurs.
- - - - - - - - - -
ranking = 1
keywords = motion
(Clic here for more details about this article)

2/3. Uniocular Pulfrich phenomenon: an abnormality of visual perception.

    We describe a patient with multiple sclerosis who experienced the Pulfrich illusion of elliptical motion of a target moving linearly when viewing the motion with one eye as opposed to the well recognised binocular manifestation of the phenomenon. The perception of the illusion was independent of the wave form or velocity characteristics of target motion or of retinal image position. We suggest that the occurrence of the phenomenon does not simply reflect delay in the visual system but is a function of an abnormality of perceptual interpretation of visual stimuli occurring at a high integrative level.
- - - - - - - - - -
ranking = 1
keywords = motion
(Clic here for more details about this article)

3/3. A bedside test to determine motion stereopsis using the Pulfrich phenomenon.

    OBJECTIVE: Many diseases induce asymmetric delays in the visual pathway, resulting in a spontaneous Pulfrich phenomenon (PP). The PP is a visual stereoillusion that may cause difficulties in persons when traveling in cars, crossing the road, or playing ball games. The authors developed and tested a simple new bedside procedure to detect PP. DESIGN: A case series. PARTICIPANTS: disease simulation in 2 normal subjects and 18 patients with optic neuritis (ON) was examined. Ninety normal subjects were studied to determine normal range of PP. INTERVENTION: The new test, called swinging pen test (SPT), is performed by oscillating a pen by hand. The SPT was compared to a gold standard, a mechanical pendulum (MP). MAIN OUTCOME MEASURES: The authors measured simulated PP in two normal subjects and PP in 18 patients with ON and 90 normal control subjects. The Pearson product-moment correlation (r) and the Spearman rank correlation (rs) between SPT and MP were calculated. RESULTS: The magnitudes of simulated PP determined with the SPT and the MP correlated well (r = 0.92, P < 0.005, and r = 0.96, P < 0.001). Correlation also was good in patients with ON (rs = 0.90, P < 0.05). The positive predictive value of the SPT was 100%, and the negative predictive value was 92%. The PP was absent in all control subjects testing with either pendulum. The normal range for PP varied from -1.40 to 1.52 msec. For the SPT, the intraobserver variability coefficient was 8.2%, and the interobserver variability coefficient was 10.5%. CONCLUSIONS: The authors believe that SPT will be of value to clinicians on bedside evaluation of motion stereopsis dysfunctions. The normal range of PP was approximately /- -1.5 msec (approximately /- -1.5 cm), corresponding to a 0.3-log unit neutral density filter).
- - - - - - - - - -
ranking = 1.6666666666667
keywords = motion
(Clic here for more details about this article)


Leave a message about 'Illusions'


We do not evaluate or guarantee the accuracy of any content in this site. Click here for the full disclaimer.